== | ==Descrição do problema== | ||
Problems associated with automatic generation of pipe feeds using the ''<IS_TS id=iNameOPStrefaPrzylaczy/>'' tool are diagnosed by means of the following message: | Problems associated with automatic generation of pipe feeds using the ''<IS_TS id=iNameOPStrefaPrzylaczy/>'' tool are diagnosed by means of the following message: | ||
* '''''<IS_TS id=strErrNieUdaloSieUlozycPrzylaczy/>'''''. | * '''''<IS_TS id=strErrNieUdaloSieUlozycPrzylaczy/>'''''. | ||
Revisão das 18h46min de 3 de novembro de 2017
| Produto | InstalSystem 5 |
| Tipo de artigo | TYPICAL PROBLEM |
| Conteúdo atualizado para versão | IS 5.0 Beta 28 |
Descrição do problema
Problems associated with automatic generation of pipe feeds using the Percurso de tubo de alimentação tool are diagnosed by means of the following message:
- Disposição automática dos tubos de alimentação não é possível - alterar percurso de tubos de alimentação ou parâmetros de Zona Q/F ou disponha manualmente os tubos de alimentação.
The message informs that pipe feeds could not be generated automatically by means of the Percurso de tubo de alimentação tool, due to the following reasons:
- specified or automatically sized arrangement spacings are too large,
- manner of component crossing Percurso de tubo de alimentação is inappropriate (for the algorithm of automatic pipe feed arrangement),
- number of component crossings Percurso de tubo de alimentação is too large,
- Percurso de tubo de alimentação components are located too close to each other,
- width of the strip within which Percurso de tubo de alimentação generates pipe feeds is too small or too large (reaches beyond the borders of the heating zone).
Solution
- Specify smaller pipe feed arrangement spacing.
- Change manner of Percurso de tubo de alimentação component arrangement.
- Increase width of Percurso de tubo de alimentação component arrangement area.
- Draw pipe feeds manually.
Depending on design circumstances, or when pipe feeds cannot be generated automatically, the tool for manual arrangement of pipe feeds can be used.
Para mais informação, ver: Manual pipe feeds editing.
Jak wyeliminować: "Brak możliwości automatycznego ułożenia przyłączy - zmień parametry SP/SPG lub ułóż przyłącza ręcznie"